Investigation of a continuous crystal PSAPD-based gamma camera

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of high resolution compact gamma camera module based on a continuous scintillation crystal using a novel charge division readout method

The objective of this study is to investigate a high performance and lower cost compact gamma camera module for a multi-head small animal SPECT system. A compact camera module was developed using a thin Lutetium Oxyorthosilicate (LSO) scintillation crystal slice coupled to a Hamamatsu H8500 position sensitive photomultiplier tube (PSPMT). A two-stage charge division readout board based on a nov...

متن کامل

Insertion of a gamma-continuous function

A necessary and sufficient condition in terms of lower cut sets are given for the insertion of a $gamma-$continuous function between two comparable real-valued functions.

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

insertion of a gamma-continuous function

a necessary and sufficient condition in terms of lower cut sets are given for the insertion of a $gamma-$continuous function between two comparable real-valued functions.

متن کامل

Investigation of Crystal Geometries for Fiber Coupled Gamma

In this work, gamma sensitive intra-operative imaging detectors using CsI(Na), CsI(T1) and NaI(T1) scintillators coupled through optical fibers were investigated with simulations and measurements. Three coupling methods were employed between the detectors and optical fiber imaging array: discrete crystals coupled one-to-one with the fibers; discrete crystals coupled through a light diffuser to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Nuclear Science

سال: 2006

ISSN: 0018-9499

DOI: 10.1109/tns.2006.875354