Investigating the structure‐function relationship using Goldmann V standard automated perimetry where glaucomatous damage is advanced
نویسندگان
چکیده
منابع مشابه
Goldmann V Standard Automated Perimetry Underestimates Central Visual Sensitivity in Glaucomatous Eyes with Increased Axial Length
PURPOSE To investigate the effect of axial length (AL) on the structure-function relationship between retinal nerve fiber layer (RNFL) thickness measurements and visual field (VF) sensitivity measured with Goldmann III and V. METHOD There were 85 eyes of 85 patients with primary open angle glaucoma included in the current study. Optical coherence tomography and VF (Humphrey Field Analyzer 24-...
متن کاملThe relationship between standard automated perimetry and GDx VCC measurements.
PURPOSE To investigate the relationship between retinal light sensitivity measured with standard automated perimetry (SAP) and retardation of the peripapillary retinal nerve fiber layer (RNFL) measured with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA). METHODS Forty-seven healthy subjects and 101 patients with glaucoma were examined with SAP and with the commercially avail...
متن کاملThe Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V
Purpose It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect ...
متن کاملRepeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.
PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...
متن کاملDetecting early to mild glaucomatous damage: a comparison of the multifocal VEP and automated perimetry.
PURPOSE To gain better understanding of the relationship between abnormalities detected by the multifocal VEP (mfVEP) compared with those detected by static achromatic, automated perimetry in patients with glaucoma. METHODS Fifty patients were studied who had open-angle glaucoma that met the following criteria: (1) a mean deviation (MD) of better than -8 dB in both eyes on the 24-2 Humphrey v...