Inverse Relationship Between Electrode Size and Lesion Size During Radiofrequency Ablation With Active Electrode Cooling
نویسندگان
چکیده
منابع مشابه
Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling.
BACKGROUND Clinical efficacy has driven the use of larger electrodes (7F, length > or =4 mm) for radiofrequency ablation, which reduces electrogram resolution and causes variability in tissue contact depending on electrode orientation. With active cooling, ablation electrode size may be reduced. The purpose of this study was to examine the effect of electrode length on tissue temperature and le...
متن کاملLesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.
BACKGROUND It is important to increase lesion size to improve the success rate for radiofrequency ablation of ischemic ventricular tachycardia. This study of radiofrequency ablation, with adjustment of power to approach a preset target temperature, ie, temperature-controlled ablation, explores the effect of catheter-tip length, ablation site, and convective cooling on lesion dimensions. METHO...
متن کاملRelationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size.
BACKGROUND Electrode-tissue contact force (CF) is believed to be a major factor in radiofrequency lesion size. The purpose of this study was to determine, in the beating canine heart, the relationship between CF and radiofrequency lesion size and the accuracy of predicting CF and lesion size by measuring electrogram amplitude, impedance, and electrode temperature. METHODS AND RESULTS Eight do...
متن کاملEffect of Electrode Size, Shape, and Placement During Electrical Stimulation
Objective: The effect of electrode size, shape, and placement during electrical stimulation of the biceps, quadriceps, and tibialis anterior muscles were studied to assess what current is required during current-controlled electrical stimulation (ESI) to reach a set muscle force, as well as to evaluate patient comfort. Methods: The electrodes used were round, square, and square with a serrated ...
متن کاملThe Effects of Subcutaneous Fat, Electrode Size and Inter-Electrode Distance During Transcutaneous Electrical Stimulation
Transcutaneous electrical stimulation is used as an adjunct therapy for obesity, where it can enable increased levels of voluntary exercise. Due to the high resistivity of subcutaneous fat tissue, however, high stimulus currents are required to evoke muscle contraction in obese subjects, possibly leading to patient discomfort. In this study, a three-dimensional finite element model of the human...