Inverse photoemission with energy resolution better than 200meV
نویسندگان
چکیده
منابع مشابه
Inverse photoemission with energy resolution better than 200 meV.
We present a spectrometer for inverse photoemission in the vacuum ultraviolet range with variable energy resolution between 400 and 165 meV full width at half maximum. The energy distribution of the electron beam used for excitation can be adjusted between 300 and 125 meV by the use of a toroidal 90 degrees electrostatic deflector combined with a slit aperture. The emitted photons are detected ...
متن کاملDevelopment of a vacuum ultraviolet laser-based angle-resolved photoemission system with a superhigh energy resolution better than 1 meV.
The design and performance of the first vacuum ultraviolet (VUV) laser-based angle-resolved photoemission (ARPES) system are described. The VUV laser with a photon energy of 6.994 eV and bandwidth of 0.26 meV is achieved from the second harmonic generation using a novel nonlinear optical crystal KBe2BO3F2. The new VUV laser-based ARPES system exhibits superior performance, including superhigh e...
متن کاملNote: low energy inverse photoemission spectroscopy apparatus.
An apparatus for the low-energy inverse photoemission spectroscopy is described. In this technique, low energy electron having kinetic energy below 4 eV is incident to the sample and detect the emitted photons in the near ultraviolet range (below 5 eV, longer than 250 nm) to investigate the unoccupied states of the solid materials. Compared with the prototype apparatus reported previously [H. Y...
متن کاملLow-energy inverse photoemission spectroscopy using a high-resolution grating spectrometer in the near ultraviolet range.
An inverse photoemission spectroscopy (IPES) apparatus using a Czerny-Turner grating spectrometer is demonstrated. Previous IPES instruments based on grating spectrometers used a concave grating and operated in the vacuum ultraviolet range. The reflectance of such gratings is lower than 20% and the aberration cannot be finely corrected leading to an energy resolution of up to 0.1 eV. In the pre...
متن کاملResolution Acuity is better than Vernier Acuity
Our impressive sensitivity to vernier offsets as compared to resolution acuity has long inspired vision researchers to study the phenomena in great detail. In this study we use the test-pedestal framework to compare resolution and vernier acuity. In these experiments the test stimulus is the same for both tasks, only the pedestals differ. When thresholds are expressed in common units of test st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2007
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.2771096