Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study

OBJECTIVES This study aimed to compare visualisation of the vocal cords and performance of intubation by anaesthetists using four different laryngoscopes while wearing full chemical protective equipment. SETTING Medical simulation center of a university hospital, department of anaesthesiology. PARTICIPANTS 42 anaesthetists (15 females and 27 males) completed the trial. The participants were...

متن کامل

A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study

BACKGROUND The efficacy of devices for difficult intubation in paediatric patients, especially with a Cormack-Lehane grade 4 view, has yet to be established. We compared intubating parameters among three devices (the Airtraq®, McGrath®, and Macintosh laryngoscopes). METHODS This study is a randomised cross-over trial. Participants were 20 anaesthetists. Each device was tested three times usin...

متن کامل

Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.

BACKGROUND The purpose of this study was to evaluate the performance of orotracheal intubation with the Miller laryngoscope compared with the Airtraq laryngoscope by emergency and pediatric physicians wearing CBRN-PPE type III on infant manikins with conventional airway. We hypothesized that in this situation, the orotracheal intubation with the Airtraq laryngoscope would be faster and more eff...

متن کامل

Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study.

OBJECTIVE Training students on simulators before allowing their direct contact with patients is well accepted. There is no clinical or manikin-based simulation study in the literature comparing tracheal intubation with Airtraq, laryngeal mask airway (LMA) CTrach and Macintosh laryngoscopes performed by medical students having no prior intubation experience. METHODS After obtaining written inf...

متن کامل

Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study.

BACKGROUND Several videolaryngoscopes are available which may facilitate tracheal intubation in difficult airways. We compared the McGrath(®) Series 5 and the Venner™ A.P. Advance™ (APA) videolaryngoscopes with a Macintosh laryngoscope by studying the performance of experienced anaesthetists using manikins in normal and difficult airway scenarios. METHODS We recruited 48 anaesthetists into a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMJ Open

سال: 2016

ISSN: 2044-6055,2044-6055

DOI: 10.1136/bmjopen-2015-010250