Intriguing Periprosthetic Fracture of Hip Stem and Proximal Femoral Replacement
نویسندگان
چکیده
منابع مشابه
Changes in Femoral Stem Geometry Reduce Intraoperative Femoral Fracture Rates in Total Hip Replacement
Intraoperative fracture rates in total hip arthroplasty (THA) have been associated with uncemented stems, anterolateral surgical approach, diagnoses other than osteoarthritis, and female gender. The purpose of this study was to investigate if changes in stem design would influence intraoperative fracture rates. 1497 THA with Bi-Metric stems were compared to 1277 THA with Echo Bi-Metric Full Pro...
متن کاملFemoral Stem Fixation in Hip Replacement
A leading problem with cementless hip replacement is thigh pain, probably due to some degree of loosening. This is most pronounced during activities such as stair climbing or getting up from a chair. Our study compares the immediate fixation of three stems in widespread clinical use, using a cadaver test simulation in which the femur was horizontal, and cyclic forces acted vertically downward o...
متن کاملEffects of Hip Geometry on Fracture Patterns of Proximal Femur
Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (ST...
متن کاملSalvage of failed total hip arthroplasty with proximal femoral replacement.
EDUCATIONAL OBJECTIVES As a result of reading this article, physicians should be able to: 1. Identify the available types of reconstruction for failed total hip arthroplasty. 2. Summarize the preoperative workup of patients with failed total hip arthroplasty and massive proximal femoral bone loss. 3. Assess the surgical technique of proximal femoral replacement for failed total hip arthroplasty...
متن کاملPeriprosthetic Atypical Femoral Fracture-like Fracture after Hip Arthroplasty: A Report of Three Cases
Atypical femoral fractures are stress or insufficient fractures induced by low energy trauma or no trauma and have specific X-ray findings. Although the American Society for Bone and Mineral Research has excluded periprosthetic fractures from the definition of an atypical femoral fracture in 2013, this is still a matter of controversy because some authors report periprosthetic fractures showing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cureus
سال: 2018
ISSN: 2168-8184
DOI: 10.7759/cureus.2496