Smell intensity monitoring using metal oxide semiconductor odor sensors during intravenous olfaction test.
The intravenous olfaction test using prosultiamine (PST) solution is simple to perform and has been used clinically in Japan. We monitored intranasal intensity of smell continuously in real time under various conditions of administration using metal oxide semiconductor odor sensors and established an optimal PST injection procedure. In this study, we found that 1) although there was fluctuation...
متن کاملHemodynamic response of the frontal cortex elicited by intravenous thiamine propyldisulphide administration.
The intravenous olfaction (IVO) test is a unique type of clinical olfactometry and is widely used in Japan. However, it is difficult to distinguish actual olfactory disturbance from feigned disturbance because the IVO test is a psychophysical test. To resolve this problem, we investigated the possibility of an objective IVO test assisted with near infrared spectroscopy (NIRS). IVO testing was p...
متن کاملThe Odor Stick Identification Test for the Japanese (OSIT-J): clinical suitability for patients suffering from olfactory disturbance.
Various olfaction tests are used clinically in the world. In Japan, T&T olfactometry and the intravenous olfaction test, the Alinamin® test, are used as a standardized olfactory test in otorhinolaryngology clinics (Zusho, 1983; Furukawa et al., 1988). In Western countries, the University of Pennsylvania Smell Identification Test (UPSIT), the Cross-cultural Smell Identification Test (CC-SIT) and...
متن کاملnormal olfaction range of rasht residents with a new test designed for the region
background: an important part of one's information from surrounding environment comes through olfactory system. so its disorders regardless of the reason can lead to many problems. an appropriate diagnostic smell test is needed to determine the normal range of olfactory sense, to evaluate patient's complaints and to determine the severity of the problem. it is also helpful in follow- up and cho...
متن کاملThe intravenous intralipid tolerance test.
The half-life of an intravenously injected bolus of intralipid 20% was measured in normal rats in order to asess its relationship to reticuloendothelial system (RES) activity. Groups of animals were studied following various treatments, and the results compared to measurement of carbon clearance in similar groups. The RES effects of silica and C parvum were confirmed by the carbon clearance tes...