Purpose To report a rare complication of non-valved glaucoma drainage device surgery. Observations An 85-year-old pseudophakic white male presented with painless vision loss and bloody tears. He was 5 weeks removed from uncomplicated non-valved glaucoma drainage device (Baerveldt 101-350, [AMO, Santa Clara, CA]). There was serosanguinous discharge without apparent source and a 25% layering hy...
متن کاملLate onset endophthalmitis associated with unexposed glaucoma valved drainage device.
We report an extremely rare presentation of late-onset endophthalmitis in a young adult patient with an unexposed Ahmed tube implant. The implant was inserted 11 years prior to presentation. There was no history of trauma or any obvious exposure on clinical examination and the tube plate was filled with purulent material. After aqueous and vitreous tap, the patient underwent intracameral, intra...
متن کاملDevelopment of a novel valved drug-eluting glaucoma implant for safe and durable reduction of intraocular pressure
For the reduction of intraocular pressure, implants are well accepted in therapy of refractory glaucoma. Encapsulation and the resulting long term failure are the major limitations of todays’ commercially available devices. This paper describes methods for the development and characterization of a novel drug-eluting microstent for glaucoma therapy. Microstents were coated with a polymer-drug co...
متن کاملClinical Experience with the M4 Ahmed Glaucoma Drainage Implant
Aim To evaluate the safety and efficacy of the M4 (porous polyethylene plate) Ahmed Glaucoma Valve (AGV) drainage implant in a multicenter retrospective study. Materials and methods A retrospective chart review of medical records of patients who had undergone the M4 Ahmed valve was performed from January 2013 to April 2015. The primary outcome measure was surgical failure defined as: Less tha...
متن کاملValved Glaucoma Drainage Devices in Pediatric Glaucoma: Retrospective Long-term Outcomes.
IMPORTANCE Relatively little data exist about the long-term outcomes of an initial glaucoma drainage device (GDD) and subsequent GDDs implanted in pediatric patients with glaucoma. OBJECTIVE To determine the long-term outcomes of the first and second GDDs and risk factors in pediatric glaucoma. DESIGN, SETTING, AND PARTICIPANTS Retrospective review of 119 eyes of 89 patients younger than 18...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Ophthalmology Case Reports
سال: 2017
ISSN: 2451-9936
DOI: 10.1016/j.ajoc.2016.11.010