Intramodality and Intermodality Comparisons of Storage Phosphor Computed Radiography and Conventional Film-Screen Radiography in the Recognition of Small Pneumoconiotic Opacities
نویسندگان
چکیده
منابع مشابه
Comparison of storage phosphor computed radiography with conventional film-screen radiography in the recognition of pneumoconiosis.
Traditional film-screen radiography (FSR) has been useful in the recognition and evaluation of interstitial lung diseases, but is becoming increasingly obsolete. To evaluate the applicability of storage phosphor digital computed radiography (CR) images in the recognition of small lung opacities, we compared image quality and the profusion of small opacities between FSR and CR radiographs. We sc...
متن کاملIntramodality and intermodality agreement in radiography and computed tomography of equine distal limb fractures.
REASONS FOR PERFORMING STUDY Computed tomography (CT) is increasingly accessible in equine referral hospitals. OBJECTIVES To document the level of agreement within and between radiography and CT in characterising equine distal limb fractures. STUDY DESIGN Retrospective descriptive study. METHODS Images from horses that underwent radiographic and CT evaluation for suspected distal limb fra...
متن کاملA flat-panel detector digital radiography and a storage phosphor computed radiography: screening for pneumoconioses.
Storage phosphor computed radiography (SR) and flat-panel detector (FPD) radiography are two types of digital X-ray utilizing different techniques. We compared these two techniques with conventional analogue chest radiograph (AR) among pneumoconiotic patients and healthy controls. Thirty individuals consisting of 20 silica-exposed ex-workers and 10 healthy controls without occupational exposure...
متن کاملEvaluation of soft-tissue foreign bodies: comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer workstation.
OBJECTIVE The study was performed to evaluate detection of soft-tissue foreign bodies using conventional radiography (film-screen radiography), computed radiography printed on films (computed radiography-hard copy), and computed radiography displayed on a computer workstation (computed radiography-soft copy). SUBJECTS AND METHODS Fifteen foreign bodies of different size, shape, and compositio...
متن کاملFilm retakes in digital and conventional radiography.
OBJECTIVE To determine the film-retake rates and causes in digital radiography comparison to conventional X-rays method. STUDY DESIGN Comparative study. PLACE AND DURATION OF STUDY Radiology Department, Aga Khan University Hospital, Karachi, from January 2004 to December 2006. PATIENTS AND METHODS X-rays of different body parts, conducted during the year 2004, with conventional radiograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chest
سال: 2011
ISSN: 0012-3692
DOI: 10.1378/chest.11-0629