Intragranular and intergranular behaviour of multifilamentary Bi-2223/Ag tapes
نویسندگان
چکیده
منابع مشابه
Hysteresis losses in BSCCO(2223)/Ag multifilamentary tapes
In order to investigate hysteresis losses on Ag-sheathed BSCCO(2223) multifilamentary tapes, we perform hysteresis loop measurements, with the external magnetic field He perpendicular to the tape surface, for different sweep rates of the magnetic field and at different temperatures T. The experimental results show a sweep rate dependence, equivalent to a frequency dependence of the hysteretic l...
متن کاملThe Influence of Structural Inhomogeneities on Intragranular Properties of Y- and Bi-based Superconductors
The measurements of temperature dependence of AC magnetic susceptibility were used to study the influence of inhomogeneities on intragranular superconducting properties of Y Ba2Cu3−XMXOY (M=Fe,X=0,005;Al,X=0,01;Cr, X=0,01), Bi1,7Pb0,2Sb0,1Sr2Ca2Cu3OY and Bi1,5Pb0,3Sb0,2Sr2Ca2Cu3OY ceramics. It is found that step-like regions are revealed on AC magnetic field dependence curves T g m(h0) of hyste...
متن کاملPreisach-type hysteresis modelling in Bi-2223 tapes
An identiication method for Preisach-type models of hysteresis is presented. By using a phenomenological Preisach-type model for hysteresis we can obtain an exact model for the magnetisation hysteresis in the cases of tapes with strip and with elliptical cross section geometries. With a parametrisation by Maclaurin series, it is possible to identify such a model for any other geometry. An addit...
متن کاملTemperature dependence of critical currents and ac transport losses in (Bi,Pb)2Sr2Ca2Cu3Ox and YBa2Cu3Oy tapes
The critical currents and self-field ac losses of YBa2Cu3Oy coated conductors and (Bi, Pb)2Sr2Ca2Cu3Ox tapes were measured at several temperatures between 45 K and the respective critical temperature. The temperature dependence of ac losses was measured at 50 Hz using the lock-in method for a transport current. The frequency dependence of ac loss was measured at 55 K for transport current frequ...
متن کاملDetermination of susceptibility to intergranular corrosion and electrochemical reactivation behaviour of AISI 316L type stainless steel
In this study, double loop electrochemical potentiokinetic reactivation (DLEPR) test was applied to determine the degree of sensitization in 316L type stainless steel, where obtained results were correlated with revealed microstructures after oxalic acid test and weight loss measurements of Streicher and Huey acid tests. Best agreement was provided with test parameters which are 1 M H2SO4 and 0...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physica C: Superconductivity
سال: 2002
ISSN: 0921-4534
DOI: 10.1016/s0921-4534(02)00947-4