Intracranial Meningioma Resection Using Frameless Stereotaxy
نویسندگان
چکیده
منابع مشابه
Frameless stereotaxy of the brain.
Today's neurosurgical journals are replete with advertisements for systems designed to provide image guidance during surgery. These so-called "frameless" stereotactic systems provide the surgeon with navigational information, relating the location of instruments in the operative field to preoperative imaging data. Such information minimizes invasiveness by more accurately selecting the best tra...
متن کاملMonocular Visual Patient Monitoring for Frameless Stereotaxy
In this paper, we propose a low cost, robust vision based system for monitoring patient movements during stereotactic radiotherapy: the Monocular Visual Patient Movement Monitoring (MVPM) System. The system consists of a light weight mouth bite with dual fiducial system used for position tracking. One set of fiducials consist of easy-to-detect checkerboard whose 3D position can be tracked using...
متن کاملIntracranial Meningioma-induced Parkinsonism
An intracranial tumor is a rare cause of secondary parkinsonism. Our patient presented to our clinic for recently-developed asymmetric parkinsonism without pyramidal signs. However, a meningioma located in the sphenoidal ridge was identified upon imaging studies. This case suggests that additional causes should be considered when approaching patients with parkinsonism and that imaging studies c...
متن کاملFrameless stereotaxy for pre-treatment planning and post-treatment evaluation of radiosurgery.
In our centre, 111 patients have been treated with linear accelerator stereotactic radiosurgery. Angiographic, CT and MRI images are generated and the target coordinates calculated in 3 dimensions. For CT scanning, cross sections of perpendicular and oblique fiducial markers are seen. For follow-up CT scans done without the frame, a virtual frame is generated by means of a computer program that...
متن کاملComparison of laser surface scanning and fiducial marker-based registration in frameless stereotaxy. Technical note.
The authors compared the accuracy of laser surface scanning patient registration using the commercially available Fazer (Medtronic, Inc.) with the conventional registration procedure based on fiducial markers (FMs) in computer-assisted surgery. Four anatomical head specimens were prepared with 10 titanium microscrews placed at defined locations and scanned with a 16-slice spiral computed tomogr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Computer Aided Surgery
سال: 1995
ISSN: 1092-9088,1097-0150
DOI: 10.3109/10929089509106825