Uterine perforation by the intra-uterine device.
The article presents 5 cases of IUD translocation in women aged 27-34; 3 of the devices were Copper-7; the others were a Copper-T and Lippes Loop. In all cases the devices' strings were missing and the devices had been localized through X-rays and sometimes through a hystero-salpingogram. The devices were removed by laparoscopy in 3 cases, and by laparotomy in 2 cases. IUD translocation is u...
متن کاملUterine perforation by the multiload CU250 intra-uterine device.
A case of perforation of the uterus by the Multiload Cu250 IUD in a 28 year old Malay woman is presented. The Multiload Cu250 is a newer device, introduced in 1974, and the mode of insertion (withdrawal) makes perforation with this IUD unlikely and to date no such case had been reported. The patient, para 3, had a period of amenorrhea of 7 weeks. A menstrual regulation procedure was performe...
متن کاملIntra-uterine fetal blood transfusion.
H M N J Herath1, A W M Wazil1, N V I Ratnatunga2, A S Badurdeen1, K G A D Weerakoon3 1Nephrology and Transplant Unit, Teaching Hospital, Kandy, 2Department of Pathology, Faculty of Medicine, University of Peradeniya, and 3Department of Parasitology, Faculty of Medicine and Allied Sciences, Rajarata University of Sri Lanka, Sri Lanka. Correspondence: HMNJH, e-mail: . Recei...
متن کاملA Case of Obstructed Labour by an Intra-Uterine Tumour
Civil Surgeon, Sagaing. A Burmese woman about 37 years of age, a multipara with five previous births, was admitted on 15th March, 1925, with severe and continuous labour pains and a history that she had been in pain for the last five days and had lost some blood at home; she had been attended by a Burmese midwife. On admission her general condition was good. On making an examination per vaginam...
متن کاملAssessment of intra-uterine growth retardation by fetal magnetocardiography
Fetal magnetocardiography allows the noninvasive registration of the prenatal cardiac electrophysiological signal. The good signal-to-noise characteristics of most biomagnetometers combined with adequate signal processing techniques generally permit the identification of the fetal deand repolarization onsets and offsets to an accuracy of 1 ms. The P wave, QRS complex and sometimes the T wave ca...