Intra-ocular pressure during cardiopulmonary bypass-a comparison of crystalloid and colloid priming solutions.
نویسندگان
چکیده
منابع مشابه
Arterial Pressure during Cardiopulmonary Bypass
A recent randomized trial of higher versus lower mean arterial pressure (MAP) during cardiopulmonary bypass (CPB) showed that higher MAP on CPB was associated with a lower incidence of overall cardiac and neurologic morbidity and mortality in coronary artery bypass graft surgery (CABG) patients. Cardiopulmonary bypass MAP was controlled pharmacologically while CPB flow was held constant for any...
متن کاملIntraocular pressure during cardiopulmonary bypass.
Intraocular pressure was measured in 24 patients undergoing elective cardiopulmonary bypass surgery. There was a rapid rise when the bypass circulation began, and this was maintained for about 30 minutes. A simultaneous drop in arterial perfusion pressure and packed cell volume occurred. We suggest that marked haemodilution is responsible for this effect, through increased ocular blood flow and...
متن کاملRisk factors for low colloid osmotic pressure during infant cardiopulmonary bypass with a colloidal prime.
Extensive variations of colloid osmotic pressure (COP) measured in the priming as well as during infant cardiopulmonary bypass motivated us to audit clinical and laboratory data to identify the risk factors for low COP at the end of bypass. Data of 73 consecutive infant patients with body weight <10 kg, who underwent elective, first time open-heart surgery between March 2005 and December 2006 w...
متن کاملA comparison of laboratory findings in coronary artery bypass surgery with and without cardiopulmonary bypass
Background : Quests for doing coronary artery bypass surgery by a technique with lower complications is going on, for this aim many studies compared patients undergoing CABG with or without cardiopulmonary bypass. This study was carried out to compare laboratory findings after coronary artery bypass in these two groups of patients. Materials and Methods: In a retrospective study, 167 patients ...
متن کاملThe Intra-Ocular Pressure of Type 2 Diabetic Patients Comparison in Diabetic Retinopathy Grades
Objective: Retinopathy is a microvascular complication of diabetes in the retina. It is hypothesized the aqueous flow decrease in patients with retinopathy which effects the Intra-ocular pressure (IOP). The purpose of this study is to determine whether a significant correlation exists between IOP and diabetic retinopathy grades. Materials and Methods: Our study is analytic cross sectional. Abo...