Interrupting performance of gas mixtures in puffer type gas circuit breaker.
نویسندگان
چکیده
منابع مشابه
Gas flow analysis of puffer-type circuit breaker using FGCBM method
This paper presents the flow field analysis in the Puffer-tyep (P-T) circuit breakers. There are many problems in analyzing the flow field in circuit breakers such as shock wave, complex geometry, moving boundary and so on. For the cold gas analysis, the flow field computation for the high voltage gas blast circuit breaker with the moving boundary by meshfree (FGCBM) method[1,2] is employed to ...
متن کاملhazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
CDM in Sub-Stations by Replacement of SF6 Gas in Circuit Breaker
This paper gives a case of large Sub-Station Clean Development Mechanism (CDM) Project to analyze CDM project’s influence on India’s Sustainable Development. SF6 gas is being extensively used in circuit breakers. SF6 gas has the highest Global warming potential which is 23900 times of Carbon Dioxide. Extensive Survey of SubStation using SF6 circuit breaker has been done in a sample state of Ind...
متن کاملInvestigation of Circuit Breaker Dielectric Performance
The violent event of a short-circuit leads to short-term exposure of circuit breaker components to extremely high current, causing thermal degradation, vaporization and deformation of some components and the deposition of surface contaminants. After short-circuit, the leakage current carried by the breaker, when voltage is applied, increases dramatically but must remain below a certain threshol...
متن کاملThe Performance of Transit Time Flowmeters in Heated Gas Mixtures
An ultrasonic transit time flowmeter was tested over Reynolds numbers from 1000 to 100 000 in a calibration facility that generates gas flows with controlled temperature and composition. The gas mixtures were composed of air, nitrogen, carbon dioxide, water vapor, and argon, and the mixture temperature ranged from 290 K to 450 K. The test program was conducted to determine the sensitivity of th...