Interobserver reliability when using the Van Herick method to measure anterior chamber depth
نویسندگان
چکیده
منابع مشابه
Interobserver reliability when using the Van Herick method to measure anterior chamber depth
INTRODUCTION The Van Herick method is a quick and easy way to estimate anterior chamber depth, which allows grading of patients according to the likelihood of having primary acute closed-angle glaucoma. However, as the test is highly subjective, measurements and thus grading may vary between observers. AIM The aim of this study was to investigate the degree of variation of Van Herick scores a...
متن کاملAnterior chamber depth during hemodialysis
BACKGROUND Exacerbation of chronic glaucoma or acute glaucoma is occasionally observed in patients undergoing hemodialysis (HD) because of anterior chamber depth changes during this therapy. PURPOSE To evaluate anterior chamber depth and axial length in patients during HD sessions. METHODS A total of 67 eyes of 35 patients were prospectively enrolled. Axial length and anterior chamber depth...
متن کاملTITLE: SOURCES OF VARIABILITY OF THE VAN HERICK TECHNIQUE FOR ANTERIOR ANGLE ESTIMATION Running title: New insights into the Van Herick technique Authors:
Background: The purpose of the present study was to investigate two potential sources
متن کاملMeasurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.
PURPOSE To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. METHODS This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-wh...
متن کاملA Novel Method of Quantitative Anterior Chamber Depth Estimation Using Temporal Perpendicular Digital Photography
PURPOSE We hypothesize that: (1) Anterior chamber depth (ACD) is correlated with the relative anteroposterior position of the pupillary image, as viewed from the temporal side. (2) Such a correlation may be used as a simple quantitative tool for estimation of ACD. METHODS Two hundred sixty-six phakic eyes had lateral digital photographs taken from the temporal side, perpendicular to the visua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Oman Journal of Ophthalmology
سال: 2017
ISSN: 0974-620X
DOI: 10.4103/ojo.ojo_142_2014