Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

Event-by-event respiratory motion correction for PET with 3D internal-1D external motion correlation.

PURPOSE Respiratory motion during PET∕CT imaging can cause substantial image blurring and underestimation of tracer concentration for both static and dynamic studies. In this study, the authors developed an event-by-event respiratory motion correction method that used three-dimensional internal-one-dimensional external motion correlation (INTEX3D) in listmode reconstruction. The authors aim to ...

متن کامل

Internal models for motion control

This paper is a review of different approaches and models underlying the voluntary control of human hand-arm movement. These models, dedicated to artificial movement simulation with application to motor control, robotics and computer animation, are categorized along at least three axis: Direct vs. Inverse models, Dynamics vs. Kinematics models, Global vs. Local models. We focus on sensory-motor...

متن کامل

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

Internal-external correlation investigations of respiratory induced motion of lung tumors.

In gated radiation therapy procedures, the lung tumor position is used directly (by implanted radiopaque markers) or indirectly (by external surrogate methods) to decrease the volume of irradiated healthy tissue. Due to a risk of pneumothorax, many clinics do not implant fiducials, and the gated treatment is primarily based on a respiratory induced external signal. The external surrogate method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientific Reports

سال: 2018

ISSN: 2045-2322

DOI: 10.1038/s41598-018-22023-3