منابع مشابه
Interlink Converter with Linear Quadratic Regulator Based Current Control for Hybrid AC/DC Microgrid
A hybrid alternate current/direct current (AC/DC) microgrid consists of an AC subgrid and a DC subgrid, and the subgrids are connected through the interlink bidirectional AC/DC converter. In the stand-alone operation mode, it is desirable that the interlink bidirectional AC/DC converter manages proportional power sharing between the subgrids by transferring power from the under-loaded subgrid t...
متن کاملFlexible Pulsed Dc- Source for Investigations of Hvdc Circuit Breaker Arc Resistance
The paper discusses the design of a flexible pulsed current source needed for experimental research of switching arcs in HVDC circuit breakers with passive resonance circuits. The source drives a current pulse from a pre-charged capacitor and forms it using an IGBT switch operated at 10kHz. The current source will be used to measure stationary and transient UIcharacteristics of switching arcs i...
متن کاملInvestigation of Circuit Breaker Dielectric Performance
The violent event of a short-circuit leads to short-term exposure of circuit breaker components to extremely high current, causing thermal degradation, vaporization and deformation of some components and the deposition of surface contaminants. After short-circuit, the leakage current carried by the breaker, when voltage is applied, increases dramatically but must remain below a certain threshol...
متن کاملONLINE CIRCUIT BREAKER MONITORING SYSTEM A Thesis
Online Circuit Breaker Monitoring System. (December 2007) Zarko Djekic, B.S., University of Novi Sad, Serbia Chair of Advisory Committee: Dr. Mladen Kezunovic Circuit breakers are used in a power system to break or make current flow through power system apparatus. Reliable operation of circuit breakers is very important to the well-being of the power system. Historically this is achieved by reg...
متن کاملAutomated Analysis of Circuit Breaker Operation
In this paper a new approach to the analysis of test results for circuit breakers is discussed. It is implemented through new software called Automated Circuit Breaker Monitoring system ACBM. The circuit breaker performance is evaluated based on the analysis of Digital Fault Recorder (DFR) recordings taken from circuit breaker control circuitry. This paper describes the testing procedure and us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Industrial Electronics
سال: 2018
ISSN: 0278-0046,1557-9948