Interlaboratory comparison material homogeneity testing

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion-controlled toluene reference material for VOC emissions testing: international interlaboratory study.

UNLABELLED The measurement of volatile organic compound (VOC) emissions from building products and materials by manufacturers and testing laboratories, and the use of the test results for labeling programs, continue to expand. One issue that hinders wide acceptance for chamber product testing is the lack of a reference material to validate test chamber performance. To meet this need, the Nation...

متن کامل

Interlaboratory comparison of simmondsin analysis

Eleven samples containing various amounts of simmondsin (S), simmondsin ferulate (SF), demethyl simmondsins (DMS) and didemethyl simmondsins (DDMS) were analyzed by five different laboratories. The samples were made from chromatographically pure simmondsin, animal feed formulations containing jojoba meal, defatted jojoba meal, water extracts of jojoba meal and combinations of these ingredients....

متن کامل

Testing Homogeneity on Large Scales

We review observational tests for the homogeneity of the Universe on large scales. Redshift and peculiar velocity surveys, radio sources, the X-Ray Background, the Lyman-α forest and the Cosmic Microwave Background are used to set constraints on inhomogeneous models and in particular on fractal-like models. Assuming the Cosmological Principle and the FRW metric, we estimate cosmological paramet...

متن کامل

Interlaboratory comparison of serum vitamin B12 assay.

The results have been compared of microbiological and radioisotope dilution (RID) assay of serum vitamin B12 by participants in national interlaboratory trials in Britain. There was wide variation between the individual participants, especially marked in the L. leichmannii microbiological assay and in the RID methods, whereas excellent correlation, reproducibility, and recovery were obtained in...

متن کامل

Interlaboratory Comparison of Magnetic Thin Film Measurements

A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Open Chemistry

سال: 2015

ISSN: 2391-5420

DOI: 10.1515/chem-2015-0084