Interferences from blood collection tube components on clinical chemistry assays
Improper design or use of blood collection devices can adversely affect the accuracy of laboratory test results. Vascular access devices, such as catheters and needles, exert shear forces during blood flow, which creates a predisposition to cell lysis. Components from blood collection tubes, such as stoppers, lubricants, surfactants, and separator gels, can leach into specimens and/or adsorb an...
متن کاملImpact of blood collection devices on clinical chemistry assays.
Blood collection devices interact with blood to alter blood composition, serum, or plasma fractions and in some cases adversely affect laboratory tests. Vascular access devices may release coating substances and exert shear forces that lyse cells. Blood-dissolving tube additives can affect blood constituent stability and analytical systems. Blood tube stoppers, stopper lubricants, tube walls, s...
متن کاملCollection of blood specimens by venipuncture for plasma-based coagulation assays: necessity of a discard tube.
The Clinical and Laboratory Standards Institute (CLSI) recently abandoned its recommendation for drawing a discard tube when performing a prothrombin time (PT)/international normalized ratio (INR) or an activated partial thromboplastin time (APTT). Because there is currently no evidence that a discard tube is necessary for more specialized coagulation assays, we studied the need for a discard t...
متن کاملEvaluation of the BD Vacutainer® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study
INTRODUCTION Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum ...
متن کاملGraphical comparisons of interferences in clinical chemistry instrumentation.
Instrument- and analyte-specific interferences can be produced by adding known concentrations of potentially interfering substances to serum from healthy volunteers. Analytical results are expressed as a percentage of the original (unaffected) result. Graphical displays of the transformed data document the conditions under which erroneous results would be probable for specimens containing the a...