Interface Property and Apparent Strength of High-Strength Hydrophilic Fiber in Cement Matrix

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Apparent Fiber Strength and Fiber - Matrix Interface Properties on Crack Bridging in Cementitious Composites

This article proposes a new theory for predicting the crack bridging performance of random short fibers involved in cementitious composites. The current theoretical model for estimating crack bridging performance of Random Short Fiber Reinforced Cement Composites (RSFRCC) under tension is limited to specific constituent properties: friction dominant fiber-matrix interface and complete fiber pul...

متن کامل

The Effect of Resin Cement Type and Cementation Technique on Bond Strength of Fiber Posts

Background: Resin cements are widely used for cementation of FRC posts, but their bond strength can be influenced by cement type and cementation technique. The aim of this study was to determine the effect of type of resin cement and cementation technique on the bond strength of fiber posts. Methods: Forty five extracted mandibular premolars with a minimum roo...

متن کامل

Strength of the Cement-Bone Interface Relies More on Interface Contact Than Cement Penetration Depth

Introduction: In cemented total hip arthroplasty, the implant needs a mechanically stable cement-bone interface for its survival. This can be achieved by adequate cement penetration into the bone lacunar and trabecular spaces. Many studies have been conducted to investigate the strength of the cement-bone interface in relation to the amount of cement penetration, but mainly on a macro-scale [1]...

متن کامل

Influence of High Temperatures on Flexural Strength of Foamed Concrete Containing Fly Ash and Polypropylene Fiber

In this study, the elevated temperature flexural strengths of lightweight foamed concrete (LFC) containing fly ash (FA) and polypropylene fiber (PF) was investigated experimentally and statistically. The variables included were the temperature degrees (in a range of 20 to 600°C), LFC densities of 600, 800, 1000, 1200 and 1400 kg/m3 and additive content. Two mixes were made by replacing 15% and ...

متن کامل

Shear Strength of Fiber-Reinforced Clayey Sands

Consolidated-drained triaxial compression tests were conducted to compare the stress-strain and volume change response of sands and clayey sands reinforced with discrete randomly distributed poly-propylene fibers. The influence of various test parameters such as fiber content (0.0%, 0.5% and 1.0% by weight), clay content (0%, 10% and 20% by weight), relative density (50% and 90%) and confining ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Materials in Civil Engineering

سال: 1998

ISSN: 0899-1561,1943-5533

DOI: 10.1061/(asce)0899-1561(1998)10:1(5)