Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

متن کامل

The Swiss IMRT dosimetry intercomparison using a thorax phantom.

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...

متن کامل

A Personal Dosimetry Intercomparison Study in Asian and Pacific Region

The IAEA/RCA (Regional Cooperative Agreement) project to strengthen and harmonize radiation protection infrastructures in Asian and Pacific region started in 1988. The number of the RCA member countries is 17 at present. In the early stages of the project, there was little information on the status of radiation protection and their technical abilities of radiation protection measurements in RCA...

متن کامل

Reference dosimetry and small - field dosimetry in external beam radiotherapy : Results from a Danish intercomparison study

max. 2000 char.): A comparison of dosimetry methods at different clinics can be used as a means to uncover systematic uncertainties in radiotherapy. To assess the current status of reference dosimetry and small-field dosimetry in clinical practice, a collaborative comparison study involving several dosimetry methods was performed by DTU Nutech at six Danish clinics. The first part of the interc...

متن کامل

Intercomparison in Cytogenetic Dosimetry among 22 Laboratories in China

As part of a regional International Atomic Energy Agency-coordinated research project with the support from the National Health and Family Planning Commission of China, 22 laboratories participated in the intercomparison in cytogenetic dosimetry in China. Slides for chromosomal aberrations were prepared by the Department of Radiation Epidemiology, National Institute for Radiological Protection,...