Inter-Observer Agreement of Spontaneous Breathing Trial Outcome
نویسندگان
چکیده
منابع مشابه
Inter-observer agreement of spontaneous breathing trial outcome.
BACKGROUND Spontaneous breathing trials (SBTs) are a very important test in the weaning process. The trial involves evaluation of multiple objective and subjective variables. These characteristics could lead to variability in interpreting outcomes with important clinical implications. We aimed to measure the inter-observer agreement between respiratory therapists when analyzing SBT outcomes. ...
متن کاملInter-Observer Agreement in Measuring Respiratory Rate
BACKGROUND Respiratory rate (RR) is an important vital sign which is strongly correlated with in-hospital mortality. At the same time, RR is the most likely vital sign to be omitted when assessing a patient. We believe that one reason for this could be the difficulty in measure the RR, since it is not read off a monitor, but counted manually. Also there is the possibility of assessment bias and...
متن کاملInter-observer agreement in myelodysplastic syndromes.
We read with great interest the recent paper by Senent et al. and the accompanying editorial on the reproducibility of WHO 2008 criteria and inter-observer agreement regarding the assessment of dysplasia for diagnosis and classification of myelodysplastic syndromes (MDS). The reproducibility of any composite criteria is mainly based on both the constituting components and the precise manner in ...
متن کاملSpontaneous Breathing Trial a Reliable Method for Weaning in Children
Introduction Mechanical ventilation may be lifesaving intervention,It can be associated with complications,Thus,successful weaning is constitutive.One of the factors which is important in successful weaning is method of weaning. It is shown that weaning is conducted successfully by using Spontaneous Breathing Trial (SBT) through T-piece and pressure support (PS) ventilation.But few studies ...
متن کاملInter-Annotator Agreement on Spontaneous Czech Language
The goal of this article is to show that for some tasks in automatic speech recognition (ASR), especially for recognition of spontaneous telephony speech, the reference annotation differs substantially among human annotators and thus sets the upper bound of the ASR accuracy. In this paper, we focus on the evaluation of the inter-annotator agreement (IAA) and ASR accuracy in the context of imper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Respiratory Care
سال: 2014
ISSN: 0020-1324,1943-3654
DOI: 10.4187/respcare.03022