Instillation of Normal Saline before Suctioning in Patients with Pneumonia

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instillation of normal saline before suctioning reduces the incidence of pneumonia in intubated and ventilated adults.

QUESTION Does the instillation of normal saline before suctioning reduce the incidence of ventilator-associated pneumonia in intubated and ventilated adults? DESIGN Randomised, controlled trial with blinded outcome assessment. SETTING The medical/surgical intensive care unit of a tertiary oncology hospital in Brazil. PARTICIPANTS Adults expected to require at least 72 hours of mechanical ...

متن کامل

Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

OBJECTIVES To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. DESIGN Randomized clinical trial. SETTING AND PATIENTS The study was conducted in a medical surgical intensive care unit of an oncologic hospit...

متن کامل

Comparing the Effect of Using Normal Saline and Distilled Water for Tracheal Suctioning on the Incidence of Ventilator-associated Pneumonia and Hemodynamic Indexes in Ventilator-dependent Patients

Background and Aims: VAP prevention is a top priority in the intensive care units. The study was conducted to compare the effect of using normal saline and distilled water for tracheal suctioning on the incidence of ventilator-associated pneumonia and hemodynamic indexes in ventilator-dependent patients. Methods: The present study is a randomized clinical trial that was conducted from 2017 to 2...

متن کامل

Level of dyspnoea experienced in mechanically ventilated adults with and without saline instillation prior to endotracheal suctioning.

The purpose of this study was to compare the level of dyspnoea with and without the use of 5-cc saline instillation prior to endotracheal suctioning of mechanically ventilated adults. A crossover, quasi-experimental design was used. Seventeen alert, mechanically ventilated adults were asked to rank their level of dyspnoea using the vertical visual analogue scale at specific time intervals surro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Yonsei Medical Journal

سال: 2002

ISSN: 0513-5796

DOI: 10.3349/ymj.2002.43.5.607