Instantaneous phasor method for obtaining instantaneous balanced fundamental components for power quality control and continuous diagnostics
نویسندگان
چکیده
منابع مشابه
An Improved Technique for the Estimation of Local Frequency, Fundamental Component Phasor and Instantaneous Symmetrical Components
Fundamental component estimation, including its phase and amplitude information along with instantaneous fundamental symmetrical components, is of great importance for grid connected power electronics converters control, namely in power conditioning applications such as Dynamic Voltage Restorers (DVRs) and Unified Power Flow Controllers (UPFCs). Several methods have been proposed to estimate th...
متن کاملA New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory
Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...
متن کاملRobust fundamental frequency estimation using instantaneous frequencies of harmonic components
This paper proposes a noise-tolerant method for fundamental frequency (F0) extraction. This method includes several new ideas, including the estimation of the instantaneous frequencies of the higher harmonic components, and the design of an adaptive weighting function based on a bandwidth equation that combines the F0 information in the harmonic components. To evaluate the proposed method, we c...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولInstantaneous model impedance control for robots
Impedance control facilitates the performance of tasks that involve contact with the environment. Two generic strategies for implementing impedance control have been described in the literature: the dynamic based approach [4] and the position based approach [7]. The second method has been introduced to eliminate the inherent sensitivity of the first method to the accuracy of the dynamic model. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Power Delivery
سال: 1998
ISSN: 0885-8977
DOI: 10.1109/61.714826