Installation for Preparing of Nanopowders by Target Evaporation with Pulsed Electron Beam

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsed Electron-Beam Heating

A pulsed, 20 kv electron beam is focussed upon a vapor-deposited thermocouple, and the resulting temperature vs. time response is studied. The experimental data show much scatter, but are consistent with the theoretical prediction that the characteristic thermal response time T is proportional to d , where d is the beam diameter at the thermocouple. From these data, for the soft-glass substrate...

متن کامل

Silicon nanowires prepared by electron beam evaporation in ultrahigh vacuum

One-dimensional silicon nanowires (SiNWs) were prepared by electron beam evaporation in ultrahigh vacuum (UHV). The SiNWs can be grown through either vapor-liquid-solid (VLS) or oxide-assisted growth (OAG) mechanism. In VLS growth, SiNWs can be formed on Si surface, not on SiO2 surfaces. Moreover, low deposition rate is helpful for producing lateral SiNWs by VLS. But in OAG process, SiNWs can b...

متن کامل

Ultraflat carbon film electrodes prepared by electron beam evaporation.

A facile method for the preparation of thin-film carbon electrodes by electron beam evaporation onto highly doped silicon is presented. The physical and electrochemical properties of these films both before and after postdeposition pyrolysis are investigated. Raman spectroscopy establishes the amorphous structure of the nonpyrolyzed carbon films and confirms the formation of graphitic carbon af...

متن کامل

An Electron Beam Heated Evaporation Source

An electron beam evaporator has been assembled, tested and used for deposition of thin nickel films. Flux and deposition rates has been measured with an oscillating quartz crystal monitor (QCM), an ion sensor wire, and visible deposition on a mirror on front of the evaporator. A thin nickel rod of 2 mm diameter was found to improve the pressure in comparison to a 6-mm nickel rod. The flux was t...

متن کامل

Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lump...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Korean Powder Metallurgy Institute

سال: 2005

ISSN: 1225-7591

DOI: 10.4150/kpmi.2005.12.3.167