Insertion Torque of Orthodontic Miniscrews According to Changes in Shape, Diameter and Length
نویسندگان
چکیده
منابع مشابه
Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length.
OBJECTIVE To determine the variation in the insertion torque of orthodontic miniscrews according to the screw length, diameter, and shape. MATERIALS AND METHODS The maximum insertion torque (MIT) was measured using a torque tester at a constant speed of 3 rotations per minute. Cylindrical and taper type of miniscrews (Biomaterials Korea Inc, Seoul, Korea) with different lengths, diameters, an...
متن کاملEvaluation of insertion torque of different orthodontic miniscrews: An in vitro study
*Department of P.O.P, college of dentistry, university of Mosul, Mosul, Iraq. Introduction Conservation of anchorage in totality has been a perennial problem to the traditional orthodontist. Conventional means of supporting anchorage have been used by either intra oral sites or relying on extra oral means. Both of these have their limitations. The extra oral forces very difficult device and som...
متن کاملComparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews – an in vitro study
BACKGROUND The aim of the present study was to evaluate the relationship between insertion torque and stability of miniscrews in terms of resistance against dislocation, then comparing a self-tapping screw with a self-drilling one. METHODS Insertion torque was measured during placement of 30 self-drilling and 31 self-tapping stainless steel miniscrews (Leone SpA, Sesto Fiorentino, Italy) in s...
متن کاملThread shape factor: evaluation of three different orthodontic miniscrews stability.
The thread shape factor (TSF) to evaluate the relationships between geometrical characteristics and mechanical properties of the temporary anchorage devices (TADs) has recently been introduced. This in vitro experimental study evaluated in 30 different tests with three TADs: ORTHOImplant (1.8 mm diameter and 10 mm length; 3M Unitek), Tomas (1.6 mm diameter and 10 mm length; Dentaurum), and Orth...
متن کاملThe effect of insertion angle on orthodontic mini-screw torque
BACKGROUND Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were use...