Infrared spectroelectrochemical configurations for in situ measurements

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In situ spectroelectrochemical analysis of quercetin in acidic medium.

The redox processes of quercetin in acidic medium (pH 1.8) were investigated on a graphite-wax electrode by cyclic voltammetry, potential-controlled UV/Vis spectra and derivative cyclic voltabsorptometry. A long-optical-path thin-layer cell was used for the spectroelectrochemical measurements. A stable quinonic product with a united conjugated structure was found to form at the first anodic pea...

متن کامل

EXCESS THERMODYNAMIC PROPERTIES CALCULATIONS FOR ALCOHOLS IN INERT SOLVENTS BASED ON FOURIER TRANSFORM INFRARED SPECTROSCOPY MEASUREMENTS

Self-association of alcohols; including ethanol, methanol, cyclopentanol and octanol in separate mixtures with inert solvents have been studied using FT-IR spectroscopy. Except for the band at 3640 cm–1 in the IR spectrum of the alcohols which is due to the monomer species, the presence of other bands in the region of stretching vibrational frequencies of OH (3100-3700 cm–1) are attributed to t...

متن کامل

Film Cooling Measurements for Novel Hole Configurations

The effect of film cooling slot exit area and shape is studied. Detailed heat transfer coefficient and film effectiveness measurements are obtained simultaneously using a single transient IR thermography technique. Two designs with a crescent shaped exit and a slot exit are considered. The results show that the crescent shaped exit provides significantly higher film cooling effectiveness than t...

متن کامل

Attenuated total reflection design for in situ FT-IR spectroelectrochemical studies.

A versatile spectroelectrochemical apparatus is introduced to study the changes in IR spectra of organic and inorganic compounds upon oxidation or reduction. The design is based on an attenuated total reflection device, which permits the study of a wide spectral range of 16,700 (600 nm)-250 cm(-1), with a small opaque region of 2250-1900 cm(-1). In addition, an IR data collection protocol is in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Serbian Chemical Society

سال: 2019

ISSN: 0352-5139,1820-7421

DOI: 10.2298/jsc190828103m