Influence of Occlusal Support of Mouthguard on Condylar Displacement during Clenching
نویسندگان
چکیده
منابع مشابه
Influence of Occlusal Interference on the Mandibular Condylar Position.
AIM The aim of this study was to determine the effect of occlusal interferences on the position of condyles. MATERIALS AND METHODS The study included 10 participants. All recordings of the condylar position were done using ultrasound jaw tracking device with six degrees of freedom. Paraocclusal tray was fixed in the lower jaw, and the artificial occlusal interference was made on the lower lef...
متن کاملEffect of clenching with a mouthguard on head acceleration during heading of a soccer ball.
Concussions are acceleration-deceleration injuries that occur when biomechanical forces are transmitted to the cerebral tissues. By limiting acceleration of the head, enhanced cervical muscle activity derived from clenching with a mouthguard (MG) may reduce the incidence or severity of concussions following impact. The purpose of this study was to investigate the effect of voluntary clenching w...
متن کاملthe influence of the neo-platonic concept of poetic imagination on wordsworth’s poetry
بر اساس نظریه افلاطون در باره شعر خلاقیت هنری مورد انتقاد قرار گرفته است. نظریه کلی در مورد شعر این بود که شعر از ظواهرتقلید میکند و نه حقیقت. چون سایه ای از حقیقت است. اما با پیدایش فلسفه نو افلاطونی، انتقاتات قبلی در مورد شعر و شاعری اصلاح شد. فلوطین در کتاب انئید، اساس خلق هنری را بر محور مُثل افلاطونی قرار داد. وی باور داشت که هنر مندان در خلق آثار هنری، تحت تاثیر مُثل افلاطونی بوده و عوالمی ...
the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation
in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.
Effect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching.
The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Japan Prosthodontic Society
سال: 2009
ISSN: 1883-6860,1883-4426
DOI: 10.2186/ajps.1.386