Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
نویسندگان
چکیده
منابع مشابه
Influence of the implant-abutment connection design and diameter on the screw joint stability
PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The in...
متن کاملRelation between implant/abutment vertical misfit and torque loss of abutment screws.
This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure...
متن کاملCorrelation between microleakage and screw loosening at implant-abutment connection
PURPOSE This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to...
متن کاملEffect of Casting Procedure on Screw Loosening of Ucla Abutment in Two Implant-abutment Connection Systems
Since Bra�nemark et al published the results of a 10-year study on osseointegration in 1977, dental implants have increasingly been used to replace missing teeth. The use of osseointegrated implants had become a successful procedure for the treatment of complete, partial edentulism, and single-tooth replacements in both the anterior and posterior regions of the mouth. Although improvements in m...
متن کاملInfluence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Medicine
سال: 2020
ISSN: 2077-0383