Influence of different air distribution on ventilation effectiveness in negative pressure hospital wards

نویسندگان

چکیده

Hospital ward is one of non-negligible potential places to occur cross-infection among patients and health workers. Air-borne transmission was regarded as the main infection route SARS-CoV-2. Preventing air-borne should be a significant measure, which could effectively mitigate risk virus infection. Based on those consideration, in this study, influence different types air distribution ventilation effectiveness modeled through Computational Fluid Dynamics (CFD) simulations. Several typical negative pressure wards same Wuhan Thunder God Mountain hospital conformed Chinese National Health Commission (NHC) guidelines were modelled. We simulated locations supply inlets, analysed buffer door compared contaminant concentration entry for The results show that required by NHC retain directional airflow from bed-zone toilet, also has better accessibility air, workers are safer avoid standing closed exhaust outlet downstream area pollutants during rounds.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial Profile of Air Contamination in Hospital Wards

  Background and Aims:Nosocomial infections cause considerable morbidity and mortality and pose high financial burden on healthcare systems. Although surface contact, surgical incisions, wounds and catheters are responsible for a high percentage of nosocomial infections, bacterial and fungal air contaminations in hospitals have an important role in development of hospital infections. The p...

متن کامل

Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide differe...

متن کامل

The ventilation of multiple-bed hospital wards: review and analysis.

BACKGROUND Although the merits of ventilating operating theatres and isolation rooms are well known, the clinical benefits derived from ventilating hospital wards and patient rooms are unclear. This is because relatively little research work has been done in the ventilation of these areas compared with that done in operating theatres and isolation rooms. Consequently, there is a paucity of good...

متن کامل

Microbial Profile of Air Contamination in Hospital Wards

Background and Aims: Nosocomial infections cause considerable morbidity and mortality and pose high financial burden on healthcare systems. Although surface contact, surgical incisions, wounds and catheters are responsible for a high percentage of nosocomial infections, bacterial and fungal air contaminations in hospitals have an important role in development of hospital infections. The purpose...

متن کامل

Concurrence of Nosocomial Infections with Microorganisms Spreading in the Air of Hospital Wards

Abstract Background and objectives: A Nosocomial infection is one of the Leading problems causing high mortality among hospitalized patients. This study aimed at confirming the concurrence of Nosocomial infections with microorganisms spreading in the air of hospital wards. Material and Methods: This study was conducted in 2009 at ValieAsr Hospital in Tehran, Iran. The Samples were taken from th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2022

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202235605022