Abstract Blockage of arteries by the formation plaques causing stenosis is a major health problem among human beings.In this study, model developed for flow through multi-stenosed elastic artery segment under effect body acceleration and slip velocity. Fluid regarded as Non-Newtonian Bingham Plastic Fluid. The equations representing are solved analytically using Perturbation Method. Result discussed velocity, wall shear stress volumetric rate varying several parameters like pulse frequency, parameter Womersley Frequency graphically.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Body Acceleration and Slip Velocity on the Pulsatile Flow of Casson Fluid through Stenosed artery

A Mathematical model for the pulsatile blood flow through stenosed artery with the effect of body acceleration and slip velocity is proposed. Blood has been represented by casson fluid equation. Analytic expression for velocity, flow rate, wall shear stress and effective viscosity is derived. Flow variables with the change of parameters are represented graphically. The effect of pulsatility, st...

متن کامل

Unsteady boundary layer flow of a Casson fluid past a wedge with wall slip velocity

In this paper an analysis is presented to understand the effect of non–Newtonian rheology, velocity slip at the boundary, thermal radiation, heat absorption/generation and first order chemical reaction on unsteady MHD mixed convective heat and mass transfer of Casson fluid past a wedge in the presence of a transverse magnetic field with variable electrical conductivity. The partial differential...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

Pulsatile flow and heat transfer of a magneto-micropolar fluid through a stenosed artery under the influence of body acceleration

With an aim to investigate the effect of externally imposed body acceleration and magnetic field on pulsatile flow of blood through an arterial segment having stenosis is under consideration in this paper. The flow of blood is presented by a unsteady micropolar fluid and the heat transfer characteristics have been taken into account. The non-linear equations that governing the flow are solved n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2332/1/012011