Influence of arterial hypotension on fractional flow reserve measurements
نویسندگان
چکیده
منابع مشابه
Standardization of Fractional Flow Reserve Measurements.
Pressure wire-based fractional flow reserve is considered the standard of reference for evaluation of the ischemic potential of coronary stenoses and the expected benefit from revascularization. Accordingly, its application in daily practice or for research purposes has to be as standardized as possible to avoid technical or operator-related artifacts in pressure recordings. This document propo...
متن کاملImpact of Right Atrial Pressure on Fractional Flow Reserve Measurements: Comparison of Fractional Flow Reserve and Myocardial Fractional Flow Reserve in 1,600 Coronary Stenoses.
OBJECTIVES This study sought to assess the impact of a wide range of mean right atrial pressure (Pra) on fractional flow reserve (FFR) measurements. BACKGROUND FFR invasively assesses the ischemic potential of coronary stenoses. FFR is calculated as the ratio of mean distal coronary pressure (Pd) to mean aortic pressure (Pa) during maximal hyperemia. The Pra is considered to have little impac...
متن کاملFractional Flow Reserve
Traditionally, coronary artery disease was assessed using coronary angiographic guidance. Significant lesions were determined by the coronary angiographer. However, interobserver variability showed a significant limitation of interpretation of coronary angiography. Stent deployment and apposition were also evaluated based on angiographic appearance only. Risk factors for stent thrombosis and in...
متن کاملDelineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements.
Hemodynamic analysis was conducted to determine uncertainty in clinical measurements of coronary flow reserve (CFR) and fractional flow reserve (FFR) over pathophysiological conditions in a patient group with coronary artery disease during angioplasty. The vasodilation-distal perfusion pressure (CFR-p(rh)) curve was obtained for 0.35- and 0.46-mm guide wires. Our hypothesis is that a guide wire...
متن کامل“Virtual” (Computed) Fractional Flow Reserve
Ma Fractional flow reserve (FFR) is the “gold standard” for assessing the physiological significance of coronary artery disease during invasive coronary angiography. FFR-guided percutaneous coronary intervention improves patient outcomes and reduces stent insertion and cost; yet, due to several practical and operator related factors, it is used in <10% of percutaneous coronary intervention proc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EuroIntervention
سال: 2015
ISSN: 1774-024X
DOI: 10.4244/eijv11i4a82