Influence of Analyte Concentration on Stability Constant Values Determined by Capillary Electrophoresis
نویسندگان
چکیده
منابع مشابه
A stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملA stability indicating capillary electrophoresis method for analysis of buserelin
A simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (BUS). The best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (pH = 3.00; 26.4 mM), at 35 °C. The sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملGFR determined by nonradiolabeled iothalamate using capillary electrophoresis.
Traditional measurements of glomerular filtration rate (GFR) in clinical practice include the measurement of serum creatinine or creatinine clearance. Increasing evidence concerning the limitation of these measurements in clinical practice and clinical trials has resulted in efforts to develop technologies that improve measurement of GFR. Recent efforts in that regard have used radioisotopic la...
متن کاملa stability indicating capillary electrophoresis method for analysis of buserelin
a simple and rapid stability indicating method based on capillary zone electrophoresis has been developed and validated for the analysis of buserelin (bus). the best separations were achieved by using a bare fused silica capillary (75 m i.d.; 65.5 cm total, 57.0 cm effective length), phosphate buffer (ph = 3.00; 26.4 mm), at 35 °c. the sample was hydrodynamically injected at 50 mbar for 5 seco...
متن کاملDetermination of Aniline and Its Derivatives in Environmental Water by Capillary Electrophoresis with On-Line Concentration
This paper describes a simple, sensitive and environmentally benign method for the direct determination of aniline and its derivatives in environmental water samples by capillary zone electrophoresis (CZE) with field-enhanced sample injection. The parameters that influenced the enhancement and separation efficiencies were investigated. Surprisingly, under the optimized conditions, two linear ra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Chromatographic Science
سال: 2016
ISSN: 0021-9665,1945-239X
DOI: 10.1093/chromsci/bmw057