Infection of Retained Defibrillator Lead Fragment after Heart Transplant
A 59-year old heart transplant recipient was admitted due to continuous pain in her left axilla. A purulent collection was found at the site of prior defibrillator placement, where a remnant proximal segment of an electric lead was found. Two years before, the patient had had pocket infection treated with revision, but without device extraction. The remnant lead was eventually removed transveno...
متن کاملFrequency and clinical impact of retained implantable cardioverter defibrillator lead materials in heart transplant recipients
End-stage heart failure patients with implantable cardioverter-defibrillator (ICD) with/without cardiac resynchronization therapy (CRT-D) often require heart transplantation (HTPL) as a last-resort treatment. We aimed to assess the frequency and clinical impact of retained ICD lead materials in HTPL patients. In this retrospective single center study, we examined the clinical records and chest ...
متن کاملCandida glabrata Infection on Retained Implantable Cardioverter Defibrillator Lead in Heart Transplant Patient Requiring Redo Upper Mini-Sternotomy Approach
We present the first documented case of a Candida glabrata infection on the retained lead of a cardiovascular implantable electronic device (CIED) in an immunosuppressed heart transplant recipient. This is the first documented case of a redo upper mini-sternotomy approach for a lead removal and innominate vein reconstruction with bovine patch. The patient is a 55 year-old male with non-ischemic...
متن کاملDefibrillator lead dislocation after manual lumbar traction
We report a 63-year-old patient with prior coronary artery bypass surgery and recent history of recurrent hospital admissions for refractory heart failure because of ischemic cardiomyopathy and sustained ventricular tachycardia. The patient underwent ICD implantation through left subclavian vein approach (Medtronic, single chamber, model-Maximo II VR, D284VRC, with 6947 ventricular active fixat...
متن کاملRetained IOL fragment and corneal decompensation after pseudophakic IOL exchange.
A 72-year-old man had exchange of a foldable silicone multifocal intraocular lens (IOL) by transection, removal, and monofocal IOL replacement. One month after the exchange, irreversible corneal edema developed and penetrating keratoplasty was performed. At the time of the corneal transplant, a small silicone fragment was discovered in and removed from the anterior chamber. Histologic evaluatio...