Inert GAS Purifier for Slac's Two-Meter Streamer Chamber
نویسندگان
چکیده
منابع مشابه
Correcting a Coriolis Meter for Two Phase Oil & Gas Flow
It is also common for flowmeters to be installed downstream of a two or three phase separator. If the well conditions change or the separator has been incorrectly sized, then it is possible that the oil liquid outlet may have some gas carry under. The effects of gas entrainment on the output of ultrasonic and Coriolis meters has been reported previously [1] [2]. It is already known that gas ent...
متن کاملFreonless gas mixtures for glass RPC operated in streamer mode
We have operated successfully glass Resistive Plate Counters (RPC) at the BELLE experiment by using a nonflammable gas mixture of 30% argon, 8% butane-silver and 62% freon, HFC-134a. This freon is nonozone depleting freon, but a freon has a high global warming potential in general. Thus a gas mixture for RPC might be desired to be freonless in the near future. We have tested the performance of ...
متن کاملMonteCarlo Simulation of Inert Gas Elimination Data
Follow this and additional works at: http://opensiuc.lib.siu.edu/im_pubs ©1988 IEEE. Published in Proceedings of the10th Annual IEEE Engineering in Medicine and Biology Conference Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers o...
متن کاملThe transfer of hydrogen from inert gas to therapeutic gas
Hydrogen is the most abundant chemical element in the universe, and has been used as an inert gas for a long time. More recent studies have shown that molecular hydrogen as a kind of antioxidant, anti-inflammatory, anti-apoptosis, gene expression and signal modulation molecule, can be used for the treatment of many diseases. This review mainly focuses on the research progresses of hydrogen in v...
متن کاملInert gas accumulation in sonoluminescing bubbles
In this paper we elaborate on the idea @Lohse et al., Phys. Rev. Lett. 78, 1359–1362 ~1997!# that ~single! sonoluminescing air bubbles rectify argon. The reason for the rectification is that nitrogen and oxygen dissociate and their reaction products dissolve in water. We give further experimental and theoretical evidence and extend the theory to other gas mixtures. We show that in the absence o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1969
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1969.4325327