Inert Gas Diffusion Method for Measurement of Blood Flow
نویسندگان
چکیده
منابع مشابه
Inert gas diffusion method for measurement of blood flow. Comparision of bolus injection to directly measured blood flow in the isolated gastrocnemius muscle.
The isolated cat gastrocnemius preparation was used to study the relation between the washout of Xenon measured by external monitoring and blood flow measured directly by a dropcounter. The experimental possibility was thereby tested of recording the total tracer bolus and its subsequent washout by external monitoring, using the height H and the corresponding area A of the washout curve. The pa...
متن کاملInert gas diffusion method for measurement of blood flow using saturation techniques. Comparison with directly measured blood flow in isolated gastrocnemius muscle of the cat.
The isolated gastrocnemius muscle of the cat was used to study the relation between the desaturation of xenon measured by external monitoring, and blood flow measured directly by a dropcounter. The metered blood flow agreed with that calculated from the initial slope of the desaturation curve from tissue equilibrated by prolonged intra-arteria] infusion and also by atraumatic gas labelling of a...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملMeasurement of Myocardial Blood Flow in Animals and Man by Selective Injection of Radioactive Inert Gas into the Coronary Arteries.
• The Kety-Schmidt method for measurement of regional blood flow was first applied to the heart by Eckenhoff et al. These investigators employed coronary sinus catheterization to measure myocardial blood flow with nitrous oxide. The use of a radioactive gas and an external detector for the measurement of organ blood flow was investigated by Conn, Lewis et al., and Lassen et al. The radioactive ...
متن کاملImproved Method for Noninvasive Measurement of Regional Cerebral Blood Flow
A clinical method for noninvasive measurement of regional cerebral blood flow (rCBF) and blood volume (rCBV) is described, based on Obrist's 10 minute, desaturation method after 1 minute inhalation of Xe. Sixteen collimated probes are placed over both hemispheres and brain stem-cerebellar regions. End-tidal Xe curves are used for correction of recirculation. KEV discriminators are set to record...