INELASTIC DYNAMIC RESPONSE CHARACTERISTICS OF TORSIONALLY UNBALANCED SINGLE-STORY MODELS : Reinforced concrete structure
نویسندگان
چکیده
منابع مشابه
Mixed nonparametric-parametric probabilistic model for earthquake reliability of an inelastic reinforced concrete frame structure
The paper is devoted to the study of uncertainties when studying buildings under seismic loading. These uncertainties are related to the simplifications used when constructing the model (model uncertainties) and to the numerical data needed at the computation stage (data uncertainties). It has been shown in previous papers that nonparametric models are able, in the case of linear dynamics, to d...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملAcrosswind Response of Reinforced Concrete Chimneys
The acrosswind response of isolated reinfe~c~d concrete chimneys of circular cross-section is studied using wind tunnel tests, full-scale measureme,~ts and response predictions based on semi-empirical methods. Three chimneys with available full-scale response observations were selected for this study to compare their measured and predicted responses. The wind tunnel experiments involved measure...
متن کاملEvaluation of Torsional Single Story Structure During Earthquake According to Canadian provision
In this article, we tried to emphasis in how the range of torsionally stiff and flexible single story buildings works. The designed base was according to provisions of the Canadian standard, 2005 NBCC. The behavior of nonlinear dynamic time history of eight building models subjected to seven horizontal bi-directional ground motions compatible with design spectra are investigated. These models c...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIJ Journal of Technology and Design
سال: 2001
ISSN: 1341-9463,1881-8188
DOI: 10.3130/aijt.7.69_1