Industrial cooling tower design and operation in the moderate-continental climate conditions
نویسندگان
چکیده
منابع مشابه
Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.
The contamination of industrial cooling towers has been identified as one cause of legionellosis, but the real risk has been underestimated. Two different disinfection treatments were tested on Legionella colonization in an industrial Cooling Tower System (CTS). Environmental monitoring of Legionella, P. aeruginosa, and a heterotrophic plate count (HPC) at 36 °C was performed from June to Octob...
متن کاملStudy of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)
Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...
متن کاملapplication of open cooling tower with radiant cooling for office space conditioning in temperate climate
0
متن کاملInfluence of annual climate variability on design and operation of waste stabilisation ponds for continental climates.
WSPs are widely used in North America, and offer huge potential for other continental climate regions. The standard design and operating protocol is robust even at high latitudes, but may be conservative elsewhere. A simple model based on first-order kinetics for biochemical oxygen demand (BOD) is used to consider some alternative design and operating protocols, using long-term daily climate re...
متن کاملPrevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legion...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thermal Science
سال: 2016
ISSN: 0354-9836,2334-7163
DOI: 10.2298/tsci16s5203l