Inductive influence of 25 kV, 50 Hz electrified single rail traction system

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An integrated methodology for 2 x 25 kV , 50 Hz traction system calculation

The paper describes an integrated calculation methodology which, by simulating railway traffic, allows analysis of the performance of 2x25 kV 50 Hz electric traction systems. This methodology performs a multiconductor electrical analysis of the traction circuit utilising ATP-EMTP software (Alternative Transient Program-Electromagnetic Transient Program) and therefore additionally allows calcula...

متن کامل

Protection setting in 2x25 kV 50 Hz railway traction systems by digital simulation

In this paper, after a short description of the problems related to the detection of short circuits in 2x25 kV 50 Hz traction systems, a methodology for the choice of the operating area of the relay for protections based on the comparison between a measured line impedance and a fixed minimum impedance is presented. The proposed methodology has been realized through the development of a procedur...

متن کامل

Measurements on 25 kV Traction Power Supply Systems

At the moment 25 kV traction power supply systems are being introduced in the Netherlands. Currently in the Netherlands a 1500 V DC system is used, however due to increasing energy demands this system is no longer sufficient. For the high-speed lines and heavy freight lines, which are under construction, the 2x25 kV AC system has been chosen. Introduction of this new technology leads to differe...

متن کامل

Recent results on the Power Quality of Italian 2x25 kV 50 Hz railways

The recordings of the pantograph voltage and current waveforms across Italian and French high speed railway lines (both Autotransformer 2x25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various rolling stock operating conditions. These indexes, that define the electrical interface ...

متن کامل

Controlling Rail Potential of DC Supplied Rail Traction Systems

Most modern DC electrified mass transit systems use a totally floating earth as their grounding strategy. A well-known problem related with totally floating systems is that the touch potentials can be dangerously high. In order to reduce the voltages on rails, several devices exist. Most of these devices allow a direct connection to earth when a certain voltage threshold is exceeded. In this pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: MATEC Web of Conferences

سال: 2018

ISSN: 2261-236X

DOI: 10.1051/matecconf/201818006004