Inducing Current on Power Cable Line under Normal Operation
نویسندگان
چکیده
منابع مشابه
Cable and Phase Identification based on Power Line Communication
Phase and cable identification is a challenging issue. Power-line communication technology is applied to identify cable and phase of power distribution systems. Power cable circuits have only a limited ability to carry higher frequencies. Typically transformers prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the cable...
متن کاملRadiological dose Assessment by Means of a Coupled WRF-HYSPLIT Model under Normal Operation of Bushehr Nuclear Power Plant
In the present work WRF model is used to generate meteorological fields for the HYSPLIT dispersion model. Sensitivity and validation of the WRF model, is conducted by utilizing different combinations of physical parameterization schemes. For this purpose, eight different configurations are examined. Assessment of the predictions of the WRF model is carried out by computing the statistical param...
متن کاملPower Line Cable Transfer Function for Modelling of Power Line Communication System
This paper presents the design of a power line communication model. Primarily, it is focused on a realization of a communication model with a power line channel. The model is composed of a PLC communication model, a model of power lines and a noise model. Power lines are modelled through a chain parameter describing the relation between the input and output voltage and current of the two-port n...
متن کاملRadiological dose Assessment by Means of a Coupled WRF-HYSPLIT Model under Normal Operation of Bushehr Nuclear Power Plant
In the present work WRF model is used to generate meteorological fields for the HYSPLIT dispersion model. Sensitivity and validation of the WRF model, is conducted by utilizing different combinations of physical parameterization schemes. For this purpose, eight different configurations are examined. Assessment of the predictions of the WRF model is carried out by computing the statistical param...
متن کاملEVALUATION OF POWER LINE CABLE FATIGUE PARAMETERS BASED ON MEASUREMENTS ON A LABORATORY CABLE TEST SPAN S.Guérard
The present paper describes experiments carried out on IREQ 1 laboratory cable test bench. Test span arrangement is a 63.15m cable span with termination ends designed so as to minimize energy dissipation. A shaker provides a vertical alternating force to the conductor. During the experiments, a maximum of information on mode shape is collected: location of nodes, antinode amplitude of vibration...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1974
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1972.94.97