Incremental dynamic analysis of underground subway station structure
نویسندگان
چکیده
Incremental dynamic analysis constitutes the basis of seismic performance evaluation and vulnerability assessment. In this paper, a typical two-story three-span subway station structure is selected as an example its incremental procedure are presented, including selection ground motion, intensity measure limit state determination. The provided in study can be for further on design underground structural systems.
منابع مشابه
Analysis of Noise and Vibration in Subway Station Hall
This study use noise and vibration analytical system to test and analyze the noise and vibration of subway station hall, draw the conclusion: analysis the noise test results when the vehicles through the subway station hall. The noise rises as the frequency increases, gets the peak value nearby 5000 Hz, the high of test point gives lesser influence to noise contribution. The vibration occurred ...
متن کاملApproximate Incremental Dynamic Analysis Using Reduction of Ground Motion Records
Incremental dynamic analysis (IDA) requires the analysis of the non-linear response history of a structure for an ensemble of ground motions, each scaled to multiple levels of intensity and selected to cover the entire range of structural response. Recognizing that IDA of practical structures is computationally demanding, an approximate procedure based on the reduction of the number of ground m...
متن کاملAnalysis of subway station capacity with the use of queueing theory
A new concept of subway station capacity (SSC) is defined according to the gathering and scattering process. A queuing network analytical model of station is created for calculating SSC, which is built by M/G/C/C state dependent queuing network and discrete time Markov chain (DTMC). Based on the definition and the analytical queuing network, a SSC optimization model is developed, whose objectiv...
متن کاملSeismic Reliability Analysis of Offshore Fixed Platforms Using Incremental Dynamic Analysis
It is generally accepted that performance-based design has to be reliability-based. Seismic performance evaluation is based on nonlinear dynamics and reliability theory taking into account uncertainties during analysis. Considering the economic importance of jacket type offshore platforms, the present research aims to assess the seismic performance of offshore steel platforms. In this study, th...
متن کاملAnalysis and Optimization of Ventilation Mode of Smoke Control System in Subway Station Fires
In the subway station fires, the most immediate threat to passengers’ life is not the direct exposure to fire, but the smoke inhalation because it contains hot air and toxic gases. Theoretical analysis and CFD simulations are applied to analyze the various possible ventilation model and obtain the optimization of ventilation mode in the subway station fires. According to the structure character...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2021
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202129303007