Increased cardiac output by downstream pumping with a reversed unidirectional intra-aortic balloon

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic dissection caused by intra-aortic balloon pumping.

lence of depression in older people in England and Wales: the MRC CFA study. Psychol Med 2007;37:1787–1795. 34. Wulsin L. Do depressive symptoms increase the risk for the onset of coronary disease? A systematic quantitative review. Psychosom Med 2003;65: 201–210. 35. Beekman A, Copeland J, Prince M. Review of community of depression in later life. Br J Psychiatry 1999;174:307–311. 36. Peters R,...

متن کامل

Intra-aortic balloon pumping: does posture matter?

BACKGROUND The effect of the posture of semirecumbent patients on the hemodynamics and performance of intra-aortic balloon (IAB) were studied in vivo and in vitro. METHODS An IAB was inserted into a glass tube filled with saline, fully inflated and deflated using an intra-aortic balloon pump (IABP). Three successive cycles were filmed at 125 frames/s with the tube positioned at various angles...

متن کامل

Intra-aortic balloon pumping: seven years' experience.

The indications for intra-aortic balloon pumping vary widely from country to country and from one cardiac surgical unit to another. Its use in Glasgow from 1976 to 1983 in 63 patients has been reviewed. Six of the patients (9.5%) had the intra-aortic balloon inserted before cardiac surgery, 43 (68.2%) at the time of surgery, and 14 (22.2%) in the postoperative period. Of the 63 patients, 11 cou...

متن کامل

Acute thoracic aortic thrombosis after intra-aortic balloon pumping.

We present two transesophageal echocardiographic images of a patient with acute myocardial infarction, demonstrating a large thrombus attached to the thoracic aortic wall, considered to be a complication of intra-aortic balloon pumping. The patient had received the device because of hemodynamic instability due to an infarct-related ventricular septal defect. Clinical manifestations which led to...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery

سال: 1977

ISSN: 0022-5223

DOI: 10.1016/s0022-5223(19)39907-6