Increase of implant temperature during laser disinfection
نویسندگان
چکیده
منابع مشابه
implant surface temperature changes during er:yag laser irradiation with different cooling systems.
peri-implantitis is one of the most common reasons for implant failure. decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. temperature increments of over 10ºc during laser application may suffice for irreversible bone damage.the purpose of this study was ...
متن کاملImplant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems
OBJECTIVE Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage. PURPOSE OF STUDY ...
متن کاملFinite element model of the temperature increase in excised porcine cadaver iris during direct illumination by femtosecond laser pulses.
In order to model the thermal effect of laser exposure of the iris during laser corneal surgery, we simulated the temperature increase in porcine cadaver iris. The simulation data for the 60 kHz FS60 Laser showed that the temperature increased up to 1.23°C and 2.45°C (at laser pulse energy 1 and 2 [micro sign]J, respectively) by the 24 second procedure time. Calculated temperature profiles show...
متن کاملcontrol of the optical properties of nanoparticles by laser fields
در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...
15 صفحه اولSimulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulses.
We have developed a two-dimensional computer model to predict the temperature increase of the retina during femtosecond corneal laser flap cutting. Simulating a typical clinical setting for 150-kHz iFS advanced femtosecond laser (0.8- to 1-μJ laser pulse energy and 15-s procedure time at a laser wavelength of 1053 nm), the temperature increase is 0.2°C. Calculated temperature profiles show good...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physica Polonica A
سال: 2019
ISSN: 1898-794X,0587-4246
DOI: 10.12693/aphyspola.135.1265