A guard trace placed near a signal line reduces commonmode radiation from a printed circuit board. The reduction effect is evaluated by the imbalance difference model, which was proposed by the authors, when the guard trace has exactly the same potential as the return plane. However, depending on interval of ground connection of the guard trace, the radiation can increase when the guard trace r...
متن کاملCommon-mode Current Due to Trace and Slit in Ground Plane and Effect of Guard Band
The common-mode (CM) current due to a trace near the PCB edge and across a slit in the ground plane is treated experimentally and by FDTD modeling. The width of the slit was 2 mm and the length was varied. The effect of a guard band with a 5 mm width is also discussed. As the slit length becomes longer, |S21| related to the CM current significantly increases. When the slit penetrates to the cen...
متن کاملthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولSuppression of Guard-Trace Resonance by Matched Termination for Reducing Common-Mode Radiation
We propose a novel technique of matching at both ends of the guard trace to suppress resonance. This approach is derived from the viewpoint that the guard trace acts as a transmission line. We examined that matched termination suppresses guard-trace resonance through simulating a circuit and measuring radiation. We found from these results that the proposed method enables guard-trace voltages t...
متن کاملReduction of Common-mode Radiation by Terminating Guard Trace with Resistors
A microstrip structure with a narrow return plane generates large common-mode radiation. The guard trace attached near the signal line can reduce common-mode radiation. In general, the guard trace needs a lot of via connections to the return plane for keeping the guard trace grounded. The guard trace with long intervals of vias causes resonance and additional radiation. We propose a novel techn...