INAPPROPRIATE HEPARINIZATION WITH A CELL SAVER
نویسندگان
چکیده
منابع مشابه
Cannulae and cell saver design: do they make a difference?
In the evolution of cardiopulmonary bypass (CPB), it is becoming increasing obvious that minimizing microembolization is critical in protecting the brain. Every component of the CPB circuit and ancillary apparatus must be evaluated and, if necessary, re-engineered with the reduction of microemboli a major focus. Cardiotomy suction has been identified as a major source of lipid microemboli. Howe...
متن کاملCell saver efficacy for coronary artery bypass surgery
Methods The study included sixty patients aged from 39 to 79 years presenting for CABS who were randomized to control or cell saver groups. We investigated blood parameters before and after surgery, ejection fraction, postoperative drainage, intraoperative parameters such as coronary artery bypass grafting type, number of graft, extracorporeal circulation and aortic cross clamping duration as w...
متن کاملThe use of cell saver system in cardiac surgery with cardiopulmonary bypass.
INTRODUCTION The use of cell saver (CS) in cardiac surgery is proposed to reduce the use of units of packed red blood cells stored (URBC), which increases morbidity, mortality and causes inflammatory reactions. OBJECTIVE The objective is to evaluate whether the use of CS decreases the use URBC, is cost /effective and beneficial to the patient. METHODS In a prospective study, between Novembe...
متن کاملLife-Saver: Flood Emergency Simulator
This paper proposes an agent-based simulation system for Dam Break Emergency Plan validation. The proposed system shows that integrating GIS data with an agent-based approach provides a successful simulation platform for the emergency plan validation process. Possible strategies to emergency plan modeling and representation are discussed, proposing a close relation with the actual workflow foll...
متن کاملExperience with systemic heparinization during cardiac catheterization by brachial arteriotomy.
Experience with systemic heparinization during cardiac catheterization by brachial arteriotomy has been investigated by a prospective study. In 253 catheterizations no complications attributable to heparinization occurred. The incidence of impaired (2 4%) and absent (i *6%) radial pulses after catheterization was lower than in some series. The majority ofcomplications were related to local trau...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 1991
ISSN: 0007-0912
DOI: 10.1093/bja/67.2.223