Aim: This research has studied psychological dynamics of infertility on referred women. Mehtods: In this research, the sample of 21 infertile women to be studies were selected through purposeful sampling. Theoretical sampling process continued until data saturation. The information was gathered and data analysis was carried out by open and axial coding. Findings: The research findings showed ps...

متن کامل

Charge circuit timeout: a sequence of events leading to failure of an implantable cardioverter-defibrillator to deliver therapy.

Since the advent of the implantable cardioverterdefibrillator (ICD) for primary prevention of sudden cardiac death, much attention has been given to the possibility of ICD or lead hardware failures resulting in inappropriate ICD function. Less attention has been given to the potential for software programming errors resulting in inappropriate device behavior. We report a case of a software prog...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Bistability in the Electric Current through a Quantum-Dot Capacitively Coupled to a Charge-Qubit

We investigate the electronic transport through a single-level quantum-dot which is capacitively coupled to a charge-qubit. By employing the method of nonequilibrium Green's functions, we calculate the electric current through quantum dot at finite bias voltages. The Green's functions and self-energies of the system are calculated perturbatively and self-consistently to the second order of inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anaesthesia

سال: 1995

ISSN: 0003-2409,1365-2044

DOI: 10.1111/j.1365-2044.1995.tb04631.x