In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
نویسندگان
چکیده
منابع مشابه
In vivo 1H NMR spectroscopy of rat brain at 1 ms echo time.
Using optimized, asymmetric radiofrequency (RF) pulses for slice selection, the authors demonstrate that stimulated echo acquisition mode (STEAM) localization with ultra-short echo time (1 ms) is possible. Water suppression was designed to minimize sensitivity to B1 inhomogeneity using a combination of 7 variable power RF pulses with optimized relaxation delays (VAPOR). Residual water signal wa...
متن کاملNMR Spectroscopy of the Rat Brain at 16.4T
S-T. Hong, D. Z. Balla, G. Shajan, C. Choi, K. Ugurbil, and R. Pohmann High-Field Magnetic Resonance Center, Max-Planck Institute for Biological Cybernetics, Tuebingen, Baden-Wuerttemberg, Germany, Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, United States, Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesot...
متن کاملIn vivo 1H NMR measurement of glycine in rat brain at 9.4 T at short echo time.
Glycine is an amino acid present in mammalian brain, where it acts as an inhibitory and excitatory neurotransmitter. The two detectable protons of glycine give rise to a singlet at 3.55 ppm that overlaps with the more intense myo-inositol resonances, and its measurement has traditionally required specific editing efforts. The aim of the current study was to reduce the signal intensity of myo-in...
متن کاملNon-invasive 1H NMR spectroscopy of the rat brain in vivo using a short echo time STEAM localization sequence.
Fully localized proton NMR spectra were obtained from the brains of normal anaesthetized rats in vivo using stimulated echo (STEAM) spectroscopy sequences. Investigations were carried out at 2.35 T using a 40 cm bore magnet equipped with an actively shielded gradient system. Localized shimming resulted in water proton linewidths of 6.5-7.8 Hz permitting excellent water suppression. Thus, high-q...
متن کاملMeasuring glucose concentrations in the rat brain using echo-time-averaged point resolved spectroscopy at 7 tesla.
Glucose has multiple functions in the brain, and there is interest in estimating in vivo concentrations rather than merely the uptake determined by nuclear medicine. Glucose can be estimated using magnetic resonance spectroscopy, but measurement is difficult due to its multiple J-coupled proton signals overlapping with other metabolite signals. To minimize the effect of interfering signals, ech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 1999
ISSN: 0740-3194,1522-2594
DOI: 10.1002/(sici)1522-2594(199904)41:4<649::aid-mrm2>3.0.co;2-g