In vivo electrical impedance measurement in human skin assessment
نویسندگان
چکیده
منابع مشابه
Electrical Impedance Analysis in Plant Tissues: Impedance Measurement in Leaves
Electrical impedance spectra (100 Hz-800 kHz) were measured in leaves of Peperomia obtusifolia L. (a succulent) and Brassica oleracea L. (cabbage). By measuring impedances at three or more inter-electrode distances in a single leaf, electrode impedance and specific tissue impedance were separated. Analysis of impedance data from B. oleracea leaves in relation to an equivalent circuit model show...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملFractional Calculus Model of Electrical Impedance Applied to Human Skin
Fractional calculus is a mathematical approach dealing with derivatives and integrals of arbitrary and complex orders. Therefore, it adds a new dimension to understand and describe basic nature and behavior of complex systems in an improved way. Here we use the fractional calculus for modeling electrical properties of biological systems. We derived a new class of generalized models for electric...
متن کاملPhase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کاملElectrical skin impedance at acupuncture points.
OBJECTIVES To test whether electrical skin impedance at each of three acupuncture points (APs) is significantly lower than at nearby sites on the meridian (MP) and off the meridian (NP). DESIGN Two instruments - Prognos (MedPrevent GmbH, Waldershof, Germany), a constant-current (DC) device, and PT Probe (designed for this study), a 100-Hz sinusoidal-current (AC) device-were used to record ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pure and Applied Chemistry
سال: 2019
ISSN: 1365-3075,0033-4545
DOI: 10.1515/pac-2018-1106