In vivo dosimetry in external beam radiotherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity

Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...

متن کامل

Skin in vivo Dosimetry in Radiotherapy

Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...

متن کامل

In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy.

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...

متن کامل

Reference dosimetry and small - field dosimetry in external beam radiotherapy : Results from a Danish intercomparison study

max. 2000 char.): A comparison of dosimetry methods at different clinics can be used as a means to uncover systematic uncertainties in radiotherapy. To assess the current status of reference dosimetry and small-field dosimetry in clinical practice, a collaborative comparison study involving several dosimetry methods was performed by DTU Nutech at six Danish clinics. The first part of the interc...

متن کامل

Biological dosimetry for breast cancer radiotherapy: a comparison of external beam and intraoperative radiotherapy

PURPOSE External beam radiotherapy (EBRT) is the gold standard adjuvant treatment after breast conserving surgery although a recent phase 3 trial has shown the non-inferiority of intraoperative radiotherapy (IORT). Radiation exposure of the heart and cardiac vessels causes an increase in morbidity and mortality following EBRT for breast cancer. We have used γ-H2AX foci formation in peripheral b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2013

ISSN: 0094-2405

DOI: 10.1118/1.4811216