In Vivo Chemical Sensors: Tackling Biocompatibility
نویسندگان
چکیده
منابع مشابه
Continuous ex vivo and in vivo monitoring with chemical sensors.
The chemical species of principal clinical interest for continuous monitoring include oxygen, carbon dioxide, pH, potassium, and glucose. Although sensors exist for all of these analytes, relatively few continuous monitors are used for blood chemistries. Reviewing the available electrochemical and optical approaches along with the expected system performance requirements provides some insight i...
متن کاملImproving the biocompatibility of in vivo sensors via nitric oxide release.
The continuous, real-time monitoring of clinically important analytes (e.g., PO2, PCO2, pH, K+, Na+, glucose, and lactate) is of great importance to human health care. Despite considerable efforts spanning several decades, the use of in vivo sensors clinically remains limited due to inadequate biocompatibility. The discovery of nitric oxide (NO) as an effective inhibitor of platelet and bacteri...
متن کاملBiocompatibility of NiTi Alloy Implants in vivo
In this study, the powders of Ni and Ti with 50.5 at.% Ni for 12 h were blended and cold pressed at the different pressures (50, 75 and100 MPa).The porous product obtained after Ni-Ti compacts were synthesized by SHS (self-propagating hightemperature synthesis) in the different preheating temperatures (200, 250 and 300oC) and heating rates (30, 60 and 90oC/min). The effects of the pressure, pre...
متن کاملAchieving Biocompatibility in Soft Sensors for Surgical Robots
INTRODUCTION Minimally invasive surgical robotics has enabled clinicians to operate with reduced trauma due to small incisions and long, slender tools. Instrument guidance remains a limiting challenge, however, for procedures in which image quality is limited and haptic feedback is unavailable, e.g., beating-heart intracardiac procedures [1]. To address this need, our group has been investigati...
متن کاملBiocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model
Biocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model Dr. Zare Jahromi, M.* - Dr. Razavi, S.M.** - Dr. Tabesh, B.*** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Chemistry
سال: 2006
ISSN: 0003-2700,1520-6882
DOI: 10.1021/ac069475k